top of page

Why Spokane Daycares Should Prioritize Air Duct Cleaning in Summer

  • Writer: Maksim Palets
    Maksim Palets
  • Aug 27
  • 5 min read
ree

Spokane summers bring wildfire smoke, ozone spikes, and heavy HVAC loads during nap and play hours. We prioritize indoor air that protects small lungs, reduces staff sick days, and keeps programs open through smoky weeks. For centers seeking reputable local support, Air Duct Cleaning Spokane in Spokane, WA provides daycare-safe HVAC and duct hygiene that aligns with best-practice standards and licensing expectations.


Spokane’s Summer Air Risks for Early Learning Programs


We prepare for recurring wildfire smoke intrusions that elevate fine particulate (PM2.5) and push the Air Quality Index (AQI) into unhealthy ranges. During the August 18–22, 2023 smoke event, Spokane peaked at an AQI of 368 (Hazardous). Regional clean air agencies consistently warn that late-summer smoke can quickly degrade air quality and trigger operational changes for youth programs.


Washington’s Children & Youth Activities Air Quality guide sets activity adjustments by AQI bands, signaling when to move children indoors and limit exertion—critical context for directors planning indoor air protection during smoke days.


Why Duct Cleaning Belongs in the Summer Plan


We address two realities: (1) smoke and pollen infiltrate occupied spaces and settle into dust reservoirs, and (2) summer cooling creates condensation that can load coils, drain pans, and nearby duct walls with residues that re-entrain particulates. Pediatric guidance underscores reducing pollutant sources and optimizing ventilation for child health; rigorous duct and HVAC hygiene removes reservoirs so filtration and ventilation perform as intended.


Federal indoor air quality guidance during wildfires directs schools and commercial buildings to prepare with higher-efficiency filtration (MERV 13 or higher during smoke events), full HVAC checks, and assured airflow—steps that work best when ducts and coils are clean enough to maintain target flows.


Standards and Targets Every Director Can Use


  • Ventilation & filtration benchmarks. Public health and engineering bodies recommend improving filtration as much as possible and using portable HEPA units in higher-risk rooms. Expert building science guidance calls for MERV 13 filtration where systems allow and designs capable of increased ventilation, with 6–8 ACH (air changes per hour) typical for education spaces. Many healthy-buildings programs advise 4–6 ACH by any mix of outdoor air and HEPA CADR.


  • CO₂ as a simple proxy. Elevated indoor CO₂ correlates with diminished cognitive performance. Practical school targets keep occupied rooms below ~800–1000 ppm while balancing smoke ingress risk. Use CO₂ as an operational cue, not a pollutant of concern.


  • Duct cleaning method standard. Specify ACR, The NADCA Standard, for assessment, cleaning, and restoration, including cleanliness verification—so you can document results for licensing files and families.


A Summer Duct & HVAC Hygiene Checklist for Daycares


  1. Pre-season inspection (late May–June). Inspect supply/return trunks, branch lines, coils, drain pans, and fan housings. Document visible debris, microbial residues, damaged liners, and airflow issues; plan cleaning windows around nap/closed hours. Follow NADCA ACR criteria to determine cleaning need.


  2. Filtration upgrades. Evaluate the air handler’s capacity for MERV 13; stock extra filters for smoke weeks. This reduces fine particle penetration and keeps internal surfaces cleaner between service intervals.


  3. Seal & repair. Seal accessible duct leaks, repair insulation, clear condensate drains, and clean coils to restore designed airflow before you measure ACH or CO₂ targets.


  4. Room-level air cleaning. Place portable HEPA units sized by CADR to add 2–4 equivalent ACH in nap rooms, infant rooms, and the infirmary.


  5. Smoke-day operations. On poor-AQI days, implement clean-room tactics: restrict outside air if advised, run HEPA continuously, maintain positive hygiene (door management, vestibules), and minimize door cycling.


  6. Post-cleaning verification. Use NADCA visual inspection criteria and surface cleanliness tests; retain a report with photos, chain of custody for filters/debris, and before/after airflow readings for licensing files.


How Professional Duct Cleaning for Daycares Should Be Scoped


We scope with infant/toddler safety and schedule realities:


  • Containment & negative pressure. Set up HEPA-filtered negative air machines; isolate work zones to keep fibers and dust from occupied areas. ACR outlines proper source removal and capture.


  • Source removal, not “fogging first.” Mechanically agitate and vacuum all contact surfaces (supply/return trunks, branches, registers, grilles), and clean coils and fan housings. Chemicals are used only as labeled and only when indicated.


  • Documentation for families. Provide a one-page summary: scope, dates, technicians’ background checks, methods, before/after photos, and measured airflow/CO₂ improvements. Align with WA licensing documentation.


Ventilation, Duct Hygiene, and Learning Conditions


Better air supports calmer nap times and fewer respiratory irritants. Health authorities recommend HEPA where possible; engineering standards quantify room targets used across schools; and research links higher ventilation to better cognitive performance in students—useful for preschool learning readiness.


Spokane-Specific Playbook for Smoke Season


  • Monitor & decide. Track local AQI dashboards and national wildfire smoke updates; when AQI reaches “Unhealthy for Sensitive Groups” (101–150) or worse, shift high-exertion play indoors per the state children’s air-quality guide and activate smoke-day HVAC settings.


  • Communicate. Post your indoor air plan, HEPA placement map, and filter replacement schedule for families and staff; share regional health department wildfire smoke FAQs for consistent messaging.


Purchasing & Maintenance Tips for Directors


  • Filter logistics. Stock summer inventory of MERV 13 filters and pre-cut gaskets; log pressure drops after cleaning to detect early loading. Pre-stocking is essential before smoke episodes.


  • CO₂ and ACH checks. Use a calibrated CO₂ meter and a simple ACH calculator (room volume + supply flow or HEPA CADR) to confirm targets; document on a one-page log per classroom.


  • Policy alignment. Align cleaning logs with national early-childhood health standards and Washington Administrative Code files to simplify renewals and parent communications.


What This Looks Like in Practice


  1. Week 1: Inspect ducts/HVAC, schedule night-work, order MERV 13 and spare HEPA filters.


  2. Week 2: Clean coils, pans, fans; source-remove debris from supply/return ductwork; sanitize only as indicated; replace filters; seal leaks.


  3. Week 3: Verify with photos and readings; set smoke-day HVAC presets; brief staff; publish parent summary.


  4. During smoke events: Follow clean-room steps; keep doors closed; run HEPA continuously; postpone high-exertion activities per the state children’s guidance.


CONCLUSION


We protect Spokane children by combining clean ducts (removing reservoirs), right-sized filtration (MERV 13 + HEPA), and verified ventilation (ACH/CO₂ targets) guided by CDC, EPA, ASHRAE, NADCA, and Washington Department of Health resources. With summer smoke and heat now routine, making duct cleaning a scheduled, standards-based action each June is the simplest way for daycares to lock in healthier air, steadier operations, and family trust.


For practical steps to stop wildfire smoke from circulating through AC vents, see our guide here.


FAQs


1) How often should a Spokane daycare clean its ducts? 

We follow NADCA ACR: clean when inspection shows debris accumulation that impacts airflow or hygiene, after major renovations, or post-smoke season if deposits are visible. For high-use childcare, that often means inspection annually and cleaning every 2–4 years depending on findings.


2) Should we open windows during smoky days to improve ventilation? 

No. During wildfire smoke events, restrict outdoor air, upgrade to MERV 13, run HEPA cleaners, and set systems to recirculate until AQI improves.


3) What indoor targets should we track to confirm healthy air? 

Aim for 4–6 ACH (outdoor air + HEPA) in classrooms, MERV 13 in central systems if compatible, and occupied CO₂ below 800–1000 ppm while balancing smoke risk. Document with simple logs for your licensing file.



 
 
 

Comments


bottom of page