How to Spot Airflow Problems in Your Home During a Spokane Heatwave

  • Writer: Maksim Palets
    Maksim Palets
  • Aug 8
  • 5 min read
ree

During an Inland Northwest heatwave, weak airflow is the difference between a livable home and a stifling one. At Air Duct Cleaning Spokane in Spokane, WA, we routinely diagnose airflow faults that quietly rob cooling performance just when Spokane bakes under triple‑digit highs.


Spokane Heatwaves: Why Airflow Fails When You Need It Most


Spokane’s July normals sit well below heatwave peaks, so multi‑day events with warm nights stress systems that depend on steady, design‑rate airflow to move heat out. The National Weather Service’s HeatRisk guidance shows that when risk levels hit red or magenta, even healthy systems can struggle if ducts leak or filters restrict flow. Local climate summaries for Spokane International Airport (GEG) highlight how far these events exceed normal conditions—compounding any airflow deficiency already present in the home.


Fast “Tell‑Tales” of Airflow Trouble (No Tools Required)


  • One room never cools while adjacent rooms do, often from a closed or undersized register, a crushed flex duct, or leakage in a hot attic.


  • AC runs nonstop, but vents feel weak—especially at the farthest registers—pointing to high static pressure or a blockage.


  • Whooshing or whistling at returns suggests starved return air or leaky return boots drawing attic or crawlspace air.


  • Dust streaks around supply grilles indicate leakage and dirt deposition at high‑velocity edges.


  • Filters clog in days, not months, a red flag for duct leakage pulling dusty air from attics or crawlspaces; ENERGY STAR estimates typical homes can lose about 20–30% of conditioned air through leaky ducts.


Data‑Driven Checks You Can Do in 15–30 Minutes


1) Supply‑vent feel test (all rooms). With the AC running, compare the weakest room to the strongest. A large imbalance implies a restriction or mis‑sized branch.


2) Filter drop and condition. If a filter bows inward or loads quickly during a heatwave, you may be over‑restricting flow (too high a MERV rating for your blower) or pulling dirt via duct leaks. Sealing and insulation often restore lost capacity.


3) Thermostat runtime ratio. If calls last much longer than usual and the setpoint isn’t reached, suspect low airflow before condemning equipment.


4) Outdoor unit “air wash.” Weak exhaust air at the condenser can indicate low indoor airflow (poor heat transfer), coil dirt, or fan issues.


5) Monitor humidity. The EPA recommends indoor relative humidity around 30–50% (and below 60%). Rising RH during long cycles often signals low airflow across the coil and reduced dehumidification.


Spokane‑Specific Wildfire Smoke Considerations


During heatwaves, smoke frequently intrudes. To protect lungs without sacrificing airflow:


  • Use MERV‑13 or higher filters only when compatible with your blower; this is widely recommended during smoke events.


  • Consider a temporary Corsi‑Rosenthal box (box fan plus MERV‑13 filters) to supplement room filtration during smoke surges.


  • Local health officials caution that when indoor air exceeds ~95°F, portable fans blowing hot air across the body can worsen heat stress; seek air‑conditioned spaces or cooling centers.


  • If AC is unavailable, check Washington State Department of Health updates for cooling‑center locations during extreme heat.


The Numbers That Matter: What “Good Airflow” Looks Like


  • Design airflow target: A practical target for many residential systems is about 400 CFM per ton of cooling capacity; performance often deteriorates below roughly 350 CFM per ton.


  • Regulatory and standards context: Federal test procedures and state energy codes commonly reference the 350–400 CFM per ton range at full load.


  • Ventilation and IAQ: For background ventilation, ASHRAE 62.2 is the recognized residential standard; ensure fresh‑air strategies don’t undermine cooling during smoke or extreme heat.


Common Root Causes We Find in Spokane Homes


  1. Leaky ducts (attics/crawlspaces). Lost supply air never reaches rooms; returns can suck in hot, dirty air, degrading capacity and indoor air quality.


  2. Starved return air. A single undersized return or a blocked grill raises static pressure and reduces supply CFM throughout the house.


  3. Filter mismatch. Jumping to a high‑MERV filter without verifying blower capability throttles airflow; pair MERV‑13 for smoke season with clean, sealed ductwork and, if needed, blower‑speed adjustments.


  4. Crushed or long flex runs and tight‑radius turns. Excess friction kills CFM at the ends of long branches.


  5. Dirty evaporator coil or blower wheel. Even a thin biofilm reduces coil heat transfer and airflow.


Room‑by‑Room Diagnostics (What to Measure)


  • Register airspeed (spot check). A handheld anemometer quickly compares rooms; large discrepancies point to duct sizing or damage.


  • Temperature split (ΔT). Typical cooling shows a supply‑to‑return temperature drop around 16–22°F when airflow is correct; a much lower ΔT with long runtimes often indicates insufficient CFM. Always compare with manufacturer coil charts.


  • Indoor RH trend. If humidity climbs during long calls, you’re likely under‑moving air across the coil or suffering from infiltration.


Quick Wins During a Heatwave (Before a Service Call)


  • Restore design airflow: Replace a loaded filter; open and clear all returns; straighten any crushed flex; fully open supply registers in problem rooms.


  • Seal visible leaks: Use mastic or UL‑rated foil tape on accessible supply and return joints; sealing is a top comfort and efficiency fix.


  • Manage ventilation intelligently: On high HeatRisk or smoky days, keep systems on recirculate, avoid open windows during the hottest and smokiest hours, and use MERV‑13 only if your system can handle the added resistance.


  • Cooling‑center backup: When indoor temps climb dangerously, plan for community cooling centers or temporarily relocate to air‑conditioned spaces.


When a Professional Test Is Worth It


  • Static pressure and airflow commissioning: Technicians measure external static pressure and set blower speed to hit ~400 CFM per ton (or the manufacturer’s target) tailored to Spokane’s dry‑summer profile. Efficiency drops off below ~350 CFM per ton.


  • Duct leakage testing: A duct‑blaster test quantifies supply and return leakage so sealing focuses where it pays back fastest.


  • Ventilation balancing: Align whole‑house ventilation with ASHRAE 62.2 so you don’t over‑ventilate during smoke or overheat the home during extreme events.


Spokane Heatwave Airflow Checklist


  1. Replace and verify the filter (compatible MERV, arrows aligned).


  2. Open and clear all returns; remove furniture or drapes blocking grilles.


  3. Confirm supply registers are fully open in problem rooms.


  4. Inspect accessible duct runs for kinks, loose collars, or gaps; seal what you can reach.


  5. Switch to recirculate during smoke; add a MERV‑13 room purifier or a DIY Corsi‑Rosenthal box for bedrooms and living areas.


  6. Track indoor RH; aim for 30–50%.


  7. If comfort still lags, schedule airflow and static‑pressure testing; adjust blower speed and repair ducts to reach the design CFM per ton.


Local Note


The National Weather Service Spokane office issues HeatRisk updates and climate summaries that help anticipate multi‑day heat stresses—use them to plan filter changes and indoor cooling strategies during each event.


CONCLUSION


Airflow—not just equipment tonnage—governs how well your Spokane home rides out a heatwave. Look for uneven room temperatures, weak far‑end registers, noisy returns, fast‑loading filters, and rising indoor humidity. Tackle simple fixes first, then validate with professional airflow and leakage testing to target ~400 CFM per ton, seal losses, and balance ventilation intelligently during smoke events. If persistent hot rooms remain, scheduling a commissioning visit with a Spokane‑based airflow specialist such as Air Duct Cleaning Spokane ensures your system is measured, tuned, and sealed to deliver design airflow when the Inland Northwest turns scorching.


Learn the pros and cons of using scented air filters during hot months in this informative blog.


FAQs


1) How do I know if my system can handle a MERV‑13 filter during smoke? 

Have a technician measure external static pressure before and after installing the filter. If pressure rises beyond the unit’s rating, use a lower‑resistance filter and add a room air purifier instead.


2) What airflow number should my contractor aim for in Spokane? 

Most residential systems are designed near 400 CFM per ton; avoid dropping much below 350 CFM per ton unless the manufacturer specifies otherwise.


3) What indoor humidity should I maintain during a heatwave? 

Aim for 30–50% RH and always keep it below 60%. If RH rises while the AC runs continuously, low coil airflow or significant infiltration is likely.



 
 
 